User manual

Freedom / Nitrox, Trimix & CCR dive computer

HW rev. 3.1, FW 1.18.2

Full manual

Section 01 - Operation and Diving

OPEN

Section 02 - Setup and Procedures

OPEN

Introduction

Use of this manual

The Divesoft Freedom is intended for use exclusively by a trained person who is capable of fully understanding the instructions contained in this manual. The technical documentation is subjected to a process of continual development and improvement. Therefore, please regularly check the website at www.divesoft.com for updates. This manual provides operating instructions for the hardware and software (firmware) version of the Divesoft Freedom written on the tittle page.

Safety

Warning: This computer calculates a decompression profile using a mathematical model. It does not know your specific physiological decompression requirements. There is always a risk of decompression sickness (DCS) for any dive profile even if you follow the dive plan prescribed by dive computer. No procedure, dive computer or dive table will prevent the possibility of DCS or oxygen toxicity!
Warning: Use backup instruments! Ensure that you have access to backup instruments to measure depth and time. Ensure that you have access to a backup method of decompression profile calculation. Never risk your life on only one source of information.
Warning: Always check the device before diving in order to ensure that the display works, the device has not run out of battery power and all settings are correct.
Warning: All software contains bugs and the firmware of the Divesoft Freedom is no exception. The computer can probably do unintended things.
Warning: This computer may malfunction at any time. The question is not whether it will fail but when it will fail. Always have a plan on how to handle failures.

Responsibility of the Divesoft Freedom user

A Divesoft Freedom user must accept the fact that diving involves risk. Adherence to everything that the user has learned in the Divesoft Freedom’s technical documentation and in training can reduce the risk but cannot eliminate it. Safety when diving is further enhanced by regular training, methodical education and adherence to good diving practices. Technical diving requires a far higher degree of care and discipline than recreational diving.
If you do not accept the risk and you are not a trained, careful and disciplined diver, do not dive with the Divesoft Freedom.

Upgradable computer

Features of the Freedom versions

Version                 Mixtures  Air  Nitrox  Oxygen  Trimix  Rebreather

Advanced Bottom Timer   -         -    -       -       -       NO  
CCR Bottom Timer        -         -    -       -       -       Yes
Basic Nitrox            1         Yes  max40%  No      No      No
Advanced Nitrox         3         Yes  Yes     Yes     No      No
Full Trimix             9         Yes  Yes     Yes     Yes     No
Closed Circuit          9+8 dil.  Yes  Yes     Yes     Yes     Yes

Hardware of all versions of the Divesoft Freedom computer is the same1 . Only the software differs. The software version can be upgraded.

Pictures in this manual are based on the Closed Circuit version of the Divesoft Freedom. Limitation of other versions are mentioned in the text.

1* The Closed Circuit version includes a cable for connection to rebreather O2 sensors.

Section 01: Quick start guide

1. Recharge battery

Use the charger that you find in the package or another suitable USB charger or a computer USB port. See "10.1 Charging" for detailed information.

2. Switch on
Hold both buttons until you feel a vibration and the display starts. The computer will be in surface mode in a few seconds.

3. Reset to factory defaults if necessary

It is not necessary to reset a new computer. If you are in doubt about the correct setting, perform the reset to factory default.
Shortly press both buttons to enter the menu. Move the cursor to Setup with the lower button and select with the upper button. Then proceed in the same way to Miscellaneous -> Factory Defaults. Then move the cursor to Factory defaults, select and confirm. Horizontal calibration starts automatically after the reset. Place the computer on a table and press any key. You will then be asked to place the computer vertically. Place the computer on the only straight side of the device and press the button again.

4. Adjust to right hand if required

Adjust display orientation to your preference. Shortly press both buttons to enter the menu. Move the cursor to Setup with the lower button and select with the upper button. Then select Setup → Preferences → Display → Orientation. (Bottom timer licence: Setup → Orientation)

5. Switch to imperial units if required

Adjust the units to your preference. Shortly press both buttons to enter the menu. Move the cursor to Setup with the lower button and select with the upper button. Then select Preferences → Units.

6. Select wrist mount

If you prefer a strap, attach the strap to the computer. If you prefer a bungee, then remove the screws holding the bars and pass the bungee through the threaded holes.
See "10.2 Wrist mount" for detailed information.

7. Switch to dive mode

In the menu select Dive → Default (OC). A brief overview of settings will appear. Verify settings and confirm with the lower button.

Now your Divesoft Freedom is prepared for simple dive with open circuit SCUBA using air.